Methods of Sampling for Fungi
Bulk material
Prefer serial dilution methods
Report results in CFU/gram of material
Guidelines based on University of Minnesota Department of Environmental Health & Safety
Surface wipes or swabs
Generally, a qualitative or semi-quantitative test method (CFU/swab)
Results can also be reported in CFU/sq inch or CFU/sq cm
Contact plates
Results in CFU/plate or CFU/area
Tape Lift or “tease tape” method
Optical microscopy: qualitative test
Identify spores and fungal structures
Vacuum samples (“micro-vac”)
For dust in carpet or upholstered furniture
Must collect ~a gram of material (2 thimbles-full)
Serial dilution, culture plates More Sampling Methods...
Stay informed about current technologies and practices. Click here to subscribe to our FREE electronic News Briefs.