Methods of Sampling for Fungi

Bulk material

  • Prefer serial dilution methods

  • Report results in CFU/gram of material

  • Guidelines based on University of Minnesota Department of Environmental Health & Safety

Surface wipes or swabs

  • Generally, a qualitative or semi-quantitative test method (CFU/swab)

  • Results can also be reported in CFU/sq inch or CFU/sq cm

Contact plates

  • Results in CFU/plate or CFU/area

Tape Lift or “tease tape” method

  • Optical microscopy: qualitative test

  • Identify spores and fungal structures

Vacuum samples (“micro-vac”)

  • For dust in carpet or upholstered furniture

  • Must collect ~a gram of material (2 thimbles-full)

  • Serial dilution, culture plates                                      More Sampling Methods...

 

 